Latest Resistance management for sustainable agriculture and improved public health
PlayIRAC Susceptibility Test Method 021in video Version 3.4October 2011

Introduction

This method relates to the adults developmental stage.

The methodology “Adult-Vial-Test for neonicotinoids”, using thiacloprid as reference, is based on the IRAC Method No. 011 for synthetic pyrethroids. It can be used for monitoring sensitivity of Meligethes spp. populations in oilseed rape to neonicotinoids. Since their introduction neonicotinoids are widely used in Europe for pollen beetle control. To support the resistance management approaches in oilseed rape it is obligatory to carry out a sensitivity monitoring.

Materials

  • Insect-proof containers
  • Fine pointed brush
  • Beakers for test liquids
  • Syringes/pipettes for liquids or weighing balance for solids
  • Acetone
  • Syringes/pipettes for making dilutions
  • 20ml glass vials
  • Vial roller (or hotdog roller)
  • Small funnel to transfer beetles to vials
  • Binocular microscope or hand lens
  • Paper towels
  • Maximum/minimum thermometer

Method

  1. Collect approximately 200 adult beetles at different locations across the infested field. Store beetles in an aerated plastic container. Place some dry paper towel at the bottom of the container, and add some oil seed rape leaves plus two or three rape inflorescences as food source (Figure 1). The insects should not be subjected to excessive temperature, humidity or starvation stress after collection. Physically handling of the beetles should be reduced to a minimum.

  2. Use the attached recording sheet for sampling details and other information that maybe useful for tracking samples and interpreting susceptibility results later on.

  3. Ship the containers as quickly as possible to the test laboratory; transportation method should avoid excessive temperature, humidity or starvation stress

  4. It is recommended that on arrival to the laboratory, the beetles be released into a ventilated holding cage (or equivalent) and left to recover overnight.

  5. The standard test neonicotinoid is thiacloprid (using as the commercially available formulation ‘Biscaya®’ (240g thiacloprid / litre in oil dispersion, preliminary trials revealed that technical material is not appropriate). Other neonicotinoids were not tested yet.

  6. The test containers are glass vials with an internal surface area of 20-80 cm2. Newly purchased vials should be cleaned of potential residues from their manufacture by soaking overnight in soapy water, rinsing with acetone and air drying for at least 4 hours before use.

  7. Determine the surface area of the glass vials by:

    • (h is the height of the vial, r is the radius of the bottom)
    • Surface Area = Area of bottom + Area of the side
    • Surface Area = π r 2 + (2 πr)* h

    vial surface area

  8. Prepare accurate dilutions of Biscaya® as follows:
    Prepare the stock solution by solving Biscaya® in distilled water (2% of the total volume of solvent) ad acetone to 100% of solvent volume. All further dilutions will be made in pure acetone.
    For thiacloprid suitable test concentrations in μg per cm2 glass surface have been determined as follows:

    • 1,44 µg/cm² (200% of the field recommended rate of 72 g ai/ha),
    • 0,72 µg/cm² (100% field rate),
    • 0.144 µg/cm² (20% field rate), and
    • acetone only for control,

    Optionally a 4% and a 0.8% of the field rate can be useful to obtain good dose response curves. Rates over 200% aren’t possible, because of the oil based formulation (the upper limit of 200% of oil-dispersed thiacloprid was determined by testing blank oil dispersion formulation without active ingredient).

  9. Glass vials should be filled with 500-1500 μl (depending on vial size, at the start of the coating process the interior walls of the vials should be completely covered by the test solution) of solution and rotated at room temperature until the acetone is completely evaporated. Because of the oil dispersion formulation and small amounts of water in the solutions, the vials have to rotate for a minimum of 2h and subjection to a further evaporation phase without rotation for a minimum of 2h (or overnight) is obligatory before locking and storing the vials. The prepared vials can be stored at room temperature (dark) for a minimum 8 weeks without a significant loss of thiacloprid.

  10. Two replicates of each concentration and control are required (i.e. 8 vials per test).

  11. Place ten beetles per vial (a funnel can be helpful in transferring the beetles to the vial), cap and store upright at 20 ± 2ºC (Figure 2).

  12. Prior to assessment of affected beetles (dead and moribund) after 24h vials are briefly shaken to differentiate alive and affected beetles more easily.

  13. Express results as percentage mortality, correcting for “untreated” (control) mortality using Abbott’s formula. Untreated mortality should be quoted, if greater than 20%, the study should be considered as invalid.

Precautions & Notes

 

  1. Where glass equipment is used it must be adequately cleaned with an appropriate organic solvent before re-use to prevent cross-contamination.
  2. This method was optimized for conducting Adult-Vial-Tests using an oil-dispersed formulation of thiacloprid. Other neonicotinoids and/or other formulations have to be verified before using in an Adult-Vial-Test. 

Comments

See examples of recording and assessment sheets by downloading the Method 021 pdf file.

We use anonymous data in cookies to understand website usage. You consent to our cookies if you continue to use this website.